01
Foot–ground distance sensing
Time‑of‑flight (ToF) sensors measure foot–ground distance during walking. The distance signal remains available during swing, complementing pressure‑based measurements during stance.
Real‑time gait‑phase detection
What I did
Designed a shoe‑mounted module with two ToF sensors, near the lateral heel and the fifth metatarsophalangeal (MTP) joint, and a threshold‑based algorithm that segments the gait cycle into six phases in real time. This work was presented at ASME ISPS 2021 [T1] and subsequently reported in JKSPE [J5].
Evaluation
One healthy participant walked on a flat indoor floor, with about 20 full gait cycles per trial set [J5]. Compared with air‑bladder pressure measurements, the distance‑based method reported swing fractions 3.6 and 5.9 percentage points lower for the left and right foot, respectively (Table 2). It also provided distance measurements during swing [J5].
Design choices. The algorithm defines six gait states from heel and forefoot contact flags, the relative sensor distances, and whether the heel distance is increasing or decreasing. After subtracting the standing offset from each distance signal, small thresholds were used for contact-state detection rather than precise near-ground ranging. During swing, successive heel readings were compared without explicitly estimating velocity [J5, Sections 3.2 and 4.2].
Figures 2, 8, and 10 from D. Lee, “Real-time Gait Phase Detection System Using Non-contact Distance Sensors”, JKSPE (2026). © Korean Society for Precision Engineering. CC BY‑NC 3.0; converted to WebP for display.
Pre-contact sensing for initial-contact load modulation
What I did
Designed the circuit and wrote the software for a foot–ground distance module (four ToF sensors, STM32 microcontroller). A labmate laid out the PCB from that circuit; I assembled and tested the boards and integrated the module into the Angel Legs M20 exoskeleton. I implemented a distance-based swing-control layer on the exoskeleton and ran treadmill walking experiments over tandem force plates with the layer off and at two settings. This was my M.S. thesis, Terminal Decision Maker Against Upcoming Surface for the Safe Locomotion of Wearable Robots.
Pilot result and status
A single-participant treadmill pilot showed 24.7%–28.9% lower vertical impulse on the anterior force plate over the first 100 ms after force onset than with the layer off [M1].
A manuscript, FDL: Foot–Ground Distance Layer for Initial‑Contact Load Modulation in a Lower‑Limb Exoskeleton, is in preparation [M1]. It builds on the thesis experiments.